Mfg Part Number: 03Y61TM-0094 FIND NO 3 | Alternate P/N: 03Y61TM0094FINDNO3 | Manufacturer: Eltech Research Inc |
NSN : 5925-01-133-2645 | NIIN : 011332645 | Item Name : circuit breaker |
CAGE Code : 0DA33 | FSC : 5925 Circuit Breakers |
Thank you for choosing to source for Circuit Breaker part 03Y61TM-0094 FIND NO 3 from Procurement Aces. We offer access to an inventory of over 2 billion new, used, obsolete, and hard-to-find items like part 03Y61TM-0094 FIND NO 3 with the NSN 5925-01-133-2645 under FSC 5925 Circuit Breakers. Furthermore, we source reliably from a list of trusted manufacturers like Eltech Research Inc, so you can rest assured that our services and products are of the highest caliber. For your ease-of-purchasing, we also ship all items to you with their qualifying certifications and manufacturing trace documentation, as applicable. All items in our database are currently available and ready-for-purchase, so we invite you to explore our website’s listings for any parts you wish to procure.
Kick off the parts procurement process by submitting a Request for Quote form with as much detail as possible, including target prices, shipping deadlines, and desired quantities. This helps our team of experts tailor a custom quotation that fits your needs within 15 minutes or less. For further inquiries, contact us at any time via phone or email; we are available to assist you around-the-clock, 24/7x365. As an ASAP Semiconductor owned and operated website, quality is the cornerstone of our operations, so we operate with a strict No China Sourcing policy, in tandem with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. Find out why our loyal customers continuously choose Procurement Aces today! NSN part 03Y61TM-0094 FIND NO 3 by manufacturers Eltech Research Inc is in stock and ready to ship.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-133-2645 Item Description: Circuit Breaker | 5925 | 011332645 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
03y61tm-0094 Find No 3 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.500 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.560 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.660 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.130 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.890 INCHES NOMINAL |
AKPX | POLE QUANTITY | 2 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.200 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND HUMIDITY RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
FREQ | FREQUENCY IN HERTZ | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 4 QUICK DISCONNECT, MALE |
![]() |